Gutmann F50/F60 Curtain Wall System

Standard curtain wall system with 50 or 60mm face width

Loading

System Description

  • Us values 0.9 to 1.5 W/m2K in accordance with DIN EN ISO 10077-2 standard
  • Identical profiles for mullion and transom, straight cutting, no transom profile notching, minimal off-cuts, rational manufacture and installation.
  • Joint connector technology for gap-free connection between transom and mullion. Identical width of inner glass gaskets at mullions and transoms.
  • Low edge radius for visually flawless transom connection.
  • Export version with Structural Glazing (SG), semi-SG and as visual SG variant.

System Properties

img
Water Tightness

1500PA

img
Wind Load

C5

img
Air Permeability

AE

Thermal Insulation

Us

1.5

Uw

0.83

1Element size: 1,230 x 1,480 mm | Ug value: 0,6 W/m2K | Glass spacer: Swisspacer Ultimate

img